To prevent access to electrical hazards by unauthorized personnel and to ensure continued
compliance to international radiated emissions requirements, all captive screws must be securely
tightened such that they cannot be loosened without the use of a tool.
Figure 4: Inserting Media Modules
Facility test call
The facility test call feature allows you to use a voice terminal to make test calls to specific trunks within
the system. The test call verifies that the accessed component is functioning properly. To use this feature,
it must be enabled on the Class of Restriction form, and you must know the facility test call access code.
The code can be retrieved by entering the SAT command
page one of the screen output.
The trunk test call accesses specific tie or CO trunks, including DS1 trunks. If the trunk is busied out by
maintenance, it will be temporarily released for the test call and returned to busyout afterwards. Before
making the test call, use
test.
NOTE:
DID trunks cannot be accessed.
NOTE:
Do not use this trunk test call procedure to test ISDN-PRI or ATM-CES trunks. For more
information about testing ISDN-PRI or ATM-CES trunks, see ATM-BCH, Test #258.
38
WARNING:
list configuration
display feature-access-codes
to determine the location of the trunk ports that you want to
Maintenance of the Avaya G350 Media Gateway
. It appears on
June 2004