Avaya Communication Manager controlled maintenance
ALARM-PT (ALARM PORT)
Station Status and Translation Audits and
Updates Test (#36)
For an analog line port that is administered as an external alarm, this test is limited to updating the
software with the switchhook state.
Table 33: TEST #36 Station Status and Translation Audits and Updates
Error
Test
Code
Result
ABORT
1004
ABORT
1006
ABORT
2000
ABORT
2100
ABORT
1
FAIL
7
FAIL
PASS
76
Description/Recommendation
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
The port received an EXT-DEV failure during the test. The test has been
aborted.
Enter test external-device-alarm port GGGVSpp to determine if
the port is reporting an EXT-DEV failure before retesting.
If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
This port has been busied out by command.
Check Error Log for Error Type 18 (port busied out). If present, release
the port with the release port command and run the test again.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
This failure does not indicate a hardware problem. The switchhook audit
failed, this condition may occur when the audit is performed at the same
time that the terminal equipment goes off-hook.
Enter test external-device-alarm port GGGVSpp to determine if the port
is reporting an EXT-DEV failure before retesting. Wait until the port has
no EXT-DEV failure before retesting
If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
The translation update failed. This does not indicate a hardware problem
but may be an internal software error.
The software and the port processor have the same status.