System Technician-Demanded Tests: Descriptions And Error Codes - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
MG-DS1 (DS1 Interface Media Module)
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented in
By clearing error codes associated with the Echo Cancellation Test, for example, you may also clear
errors generated from other tests in the testing sequence.
Table 106: Technician-Demanded Tests
Order of Investigation
Echo Cancellation Test
(#1420)
Control Channel Loop Test
(#52)
NPE Connection Audit Test
(#50)
NOTE: This test will ABORT
with Error Code 1412
Loss of Signal Alarm Inquiry
Test (#138)
Blue Alarm Inquiry Test
(#139)
Red Alarm Inquiry Test (#140)
Yellow Alarm Inquiry Test
(#141)
Major Alarm Inquiry Test
(#142)
Minor Alarm Inquiry Test
(#143)
Slip Alarm Inquiry Test (#144)
Misframe Alarm Inquiry Test
(#145)
Translation Update Test (#146)
SAKI Sanity Test (#53)
Internal Looparound Test
(#135)
Note: This test will ABORT
with Error Code 1412
*D = Destructive; ND = Nondestructive
184
Table 106, Technician-Demanded Tests,
Short
Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Maintenance of the Avaya G350 Media Gateway
on page 184.
Reset
test
Board
ds1-
Sequence
loop
D/ND*
D
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
X
D
X
D
June 2004