Signaling Link Board Check (#643) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Signaling Link Board Check (#643)

This test checks the health of the MM710 Interface transporting the ISDN-PRI Signaling Link Port
Table 77: Test #643 Signaling Link Board Check
Error
Test
Code
Result
ABORT
1700
ABORT
8
FAIL
PASS
Any
NO
BOARD
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Internal System Error
Retry the command at 1-minute intervals for a maximum of 5 times.
If the test continues to abort, escalate the problem.
Rollabout video abort. The PRI terminal adapter associated with this D-
channel port is detached from the Media Module. This is normal when
the rollabout video feature is enabled. To complete a test on this port, do
one of the following:
Re-attach the disconnected PRI terminal adapter
Disable the rollabout video feature on this board by entering change
ds1 GGGVSpp and set the field labeled "Alarm when PRI Endpoint
Detached?" to "y."
The MM710 is not in-service.
Check the Hardware Error Log for entries logged against DS1 MM and
consult the DS1 Interface Media Module Maintenance documentation for
repair procedures.
The MM-DS1 Interface Media Module transporting the ISDN-PRI
Signaling Link Port is in-service.
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the MG-DS1 interface if it is not
already administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board long command.
This should re-establish the linkage between the internal ID and the port.
ISDN-LNK (ISDN-PRI Signaling Link Port)
139

Advertisement

Table of Contents
loading

Table of Contents