DIG-LINE Station Lamp Updates Test (#16)

This test lights all lamps on the terminal as specified. The lamp updates will run only if the station is in-
service. The status of the station is checked and the lamp updates are blocked from taking place if the
station is not in the in-service state. This test does not affect the status of the Message Waiting lamp.
Table 67: TEST #16 DIG-LINE Station Lamp Updates Test 1 of 2
Error
Test
Code
Result
ABORT
1
ABORT
3
ABORT
1000
ABORT
1392
ABORT
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
This port may have been busied out by system technician.
Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port via the release station
<extension> command and run the test again.
Make sure that the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
Station may be in ready-for-service or out-of-service state.
Use status station command to verify state of station.
Make sure the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port may be
busy with a valid call.
Use display port GGGVSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
This port is currently a TTI port and the test will not execute on it.
Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a "t" for the port).
If either list config or display port indicates that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a TTI
port, the abort is correct, and no action is necessary.
DIG-LINE (Digital Line)