Table 135: TEST #53 SAKI Sanity Test
Error
Test
Code
Result
None
ABORT
1005
ABORT
1015
ABORT
2100
ABORT
1
FAIL
2
FAIL
PASS
Any
NO
BOARD
238
Description/ Recommendation
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
If the Media Module needs to be reset,
Gateway system, and the DS1
timing for the platform, it cannot be reset without major platform disruptions (Note:
For this type of system the sync timing source is local to the G350). Set the
synchronization timing source to another DS1 interface Media Module
located in the same G350 and retest. See
page 40.
If the Media Module needs to be reset, then set synchronization to another
DS1 interface Media Module or the Tone-Clock Media Module and try
again. Refer to SYNC (Synchronization) Maintenance documentation.
Port is not out-of-service.
Busy out the Media Module.
Execute command again.
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
The Media Module failed to reset.
The Media Module failed to restart.
Execute command again.
If the problem persists, replace the Media Module.
The Media Module initializes correctly.
Run the short test sequence.
This is normal if the test is being done when (a) the board is not physically
in the system or (b) the system is booting up. Otherwise, there is some
inconsistency between the physical configuration and the data kept in the
system.
Verify that the board is physically in the system.
Verify that the system is not in a stage of booting up.
Retry the command at 1-minute intervals for a maximum of 5 times.