Plat-Alm (Platform Alarms); System Technician-Demanded Tests: Descriptions And Error Codes; Tie-Ds1 (Ds1 Tie Trunk) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

PLAT-ALM (Platform Alarms)

The PLAT_ALM is a virtual MO used by Communication Manager to keep track of Media Server alarms.
A MAJOR, MINOR, or WARNING alarm can be logged against this MO to indicate the presence of one
or more Media Server alarms.
A technician who is using the SAT and finds an alarm against the PLAT-ALM MO must:
1
Log into the Media Server's Web interface.
2
To see the Media Server's current list of alarms, select the Display Alarms option.
3
To troubleshoot and clear the problems, follow the procedures for the appropriate MOs listed in
the display.
NOTE:
After repairing the Media Server, clear every Media Server alarm. This action will also
clear any alarms associated with the PLAT-ALM MO.
System Technician-Demanded Tests:
Descriptions and Error Codes
There are no System Technician-Demanded Tests associated with this MO.

TIE-DS1 (DS1 Tie Trunk)

Table 121: TIE-DS1 (DS1 TIE TRUNK)
MO Name (in
Alarm Log)
TIE-DS1*
TIE-DS1
TIE-DS1
See MG-DS1 documentation if the tie trunk is on a MM710 Media Module Media Module.
*
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the set
**
options command and that at least 75% of the trunks in this trunk group are alarmed.
Many trunk problems are caused by incorrect settings of parameters on the trunk group administration
form. Settings must be compatible with the local environment and with parameter settings on the far-end.
Refer to "Administrator's Guide for Avaya Communication Manager, 555-233-506" for information on
how to administer trunks. The Application Notes section of that book shows the correct settings for
administrable timers and other parameters on a country-by-country basis.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Alarm Level
Initial Command to Run
MAJOR**
test trunk grp/mbr l
MINOR
test trunk grp/mbr l
WARNING
test trunk grp/mbr
PLAT-ALM (Platform Alarms)
Full Name of MO
DS1 Tie Trunk
DS1 Tie Trunk
DS1 Tie Trunk
219