Control Channel Looparound Test (#52) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Control Channel Looparound Test (#52)

This test queries the Media Module for its Media Module vintage to verify angel communication.
Table 107: Test #52 Control Channel Looparound Test
Error
Test
Code
Result
None
ABORT
2100
FAIL
PASS
Any
NO
BOARD
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
The Media Module failed to return the Media Module code or vintage.
Retry the command a maximum of 5 times.
If the problem continues, replace the Media Module.
Retry the command a few times a maximum of 5 times.
Communication with this Media Module is successful.
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the MG-DS1 if it is not already
administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board long command.
This should re-establish the linkage between the internal ID and the port.
MG-DS1 (DS1 Interface Media Module)