Table 87: Service States 2 of 2
Service State
in-service
*ISDN-TRK alarms; alarms against other objects may also be present.

Error Log Entries and Test to Clear Values

Table 88: DS1 ISDN Trunk Error Log Entries
Error
Aux
Type
Data
0*
0
1(a)
Any
15(b)
Any
18
0
19(c)
0
129(d)
130(e)
257(f)
Any
513(g)
Any
769(h)
Any
1025
0
1793(i)
Any
3073(j)
Any
3585(k)
Any
3841(l)
Any
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
**Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Alarm*
Possible Cause
Warning
The far-end trunk is being
tested.
None
Normal operating state
Associated Test
Alarm Level
Any
Any
None
Audit and Update
Test (#36)
busyout trunk
grp/mbr
None
None
WARNING
None
WARNING
None
None
WARNING
None
None
None
Service State Audit
(#256)
None
None
WARNING
ISDN-TRK (DS1 ISDN Trunk)
Possible Solution
Check status of the far-end
switch. Wait for testing to
finish.
On/Off
Board
Test to Clear Value
Any
test port GGGVSpp
test port GGGVSpp
release trunk grp/mbr
OFF
test port GGGVSpp
ON
test port GGGVSpp
test port GGGVSpp
OFF
test port GGGVSpp
test port GGGVSpp
test port GGGVSpp
test port GGGVSpp
none
OFF
None