Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port's message lamp state (if it has one) and translations with information in
the software.
Table 38: TEST #36 Station Status and Translation Audits and Updates 1 of 2
Error
Test
Code
Result
ABORT
1004
ABORT
1005
ABORT
1006
ABORT
2000
ABORT
2100
ABORT
1
FAIL
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Necessary system resources could not be allocated to run this test.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
A valid call seized the port during the test and aborted the test.
Use the display board GGGVSpp command to determine the station
extension.
Use the status station extension command to determine the service
state of the port.
If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
The port is out-of-service. The busy station extension command has
been given to this port.
Look for error type 18 (port busied out) for this port. If this error is
present, release the port (release station extension ), and run the test
again.
Make sure that the terminal is connected and in service, and then retest.
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
The switchhook audit failed. This result does not indicate a hardware
problem. The other updates were not performed because of this failure.
This may occur if the audit is performed at the same time the terminal
equipment goes off-hook.
Use the status station extension command to determine when the
port is available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to fail, escalate the problem.