Table 39: TEST #48 Station Present Test 1 of 2
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1005
ABORT
1008
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/Recommendation
Necessary system resources could not be allocated to run this test.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system's Music-On-Hold port when it is
off-hook, which it usually is.
Enter display port GGGVSpp to determine the station's extension.
Enter status station extension to determine the service state of the
port.
If the port is in use, wait until the port is idle. Retry the command at 1-
minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
A valid call seized the port during the test and aborted the test.
Use the display port GGGVSpp command to determine the station
extension.
Use the status station extension command to determine the service
state of the port.
If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
A ringing circuit could not be allocated. Retry the command at 1-minute
intervals no more than 5 times.
Check for Error Type 257 in the hardware error log. Resolve, if present.
Administration has disabled the test. The default for the Test? field on
the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
To enable the test for a particular station being tested, enter change
station extension .
Change the Test? field on the station form to y.
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
AN-LN-PT (Analog Line Port)