Error Log Entries And Test To Clear Values - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
DIOD-TRK (DIOD Trunk)

Error Log Entries and Test to Clear Values

Table 70: DIOD Trunk Error Log Entries
Error
Type
0*
15 (b)
18
769 (a)
1537 (f)
2561 (a,d)
2817 (a,e)
3073 (a,c)
3585 (a,c)
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
**Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command. If the Minor alarm is not downgraded by the set-options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Notes:
These are in-line errors that have no specific test associated with them. Refer to the following
Table 71, DIOD Trunk Errors without Associated Tests,
appropriate action.
This is a software audit error and does not indicate any hardware malfunction. Run the Short Test
Sequence and investigate associated errors.
These errors cause the Dial Tone Test (#0) to run and are only considered a problem if the Dial
Tone Test fails (in which case Error Type 1537 also appears). In this case, the trunk may be put in
''Ready-for-Service'' state (shown as ''disconnected'' by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its procedures.
Aux data 57376
Aux data 57424
Single polarity ringing current
prevent the incoming call from being accepted. This error code is logged for information purposes
only and does not cause additional testing to occur.
Late CO Trunk release
the PBX dropped the call. This error code is only logged as an informational event and causes no
other testing to occur.
132
Aux
Data
Associated Test
0
Any
any
Port Audit Update
Test (#36)
0
Busyout trunk
grp/mbr
57392
None
57345
None
57393
None
57376
None
57424
None
No loop current on incoming call
No loop current on outgoing call
This error results from abnormal ringing current, but does not
This indicates that the CO releases the trunk at least four minutes after
On/Off
Alarm Level
Board
Any
Any
WARNING
MAJ/MIN/WRN**
ON
on page 133 for an explanation and
Maintenance of the Avaya G350 Media Gateway
Test to Clear
Value
test port sh
release trunk
June 2004