Co Demand Diagnostic Test (#3) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Table 49: Test #0 Dial Tone Test 3 of 3
Error
Test
Code
Result
1009
PASS
PASS
0
NO
BOARD

CO Demand Diagnostic Test (#3)

For ground start trunks, port Media Module relays are operated and checks are made to see if the port can
detect and apply ground on the Tip lead. This test also verifies that there is no external ground on the
Ring lead. In the absence of other failures, the Media Module should be replaced only if this test fails
with the CO line disconnected.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Detected tone was not pure dial tone. No action required.
Trunk was seized, and dial tone was detected. User-reported
troubles on this port should be investigated by using other port tests
and by examining trunk or external wiring.
The test could not relate the internal ID to the port.
1
Check to ensure that the board translations are correct.
Translate the board, if necessary.
2
Use the busyout board command.
3
Use the reset board command.
4
Use the release busy board command.
5
Use the test board command. This should re-establish the
linkage between the internal ID and the port.
CO-TRK (Analog CO Trunk)
3 of 3
101