Control Channel Looparound Test (#52) - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Control Channel Looparound Test (#52)

This test queries the Media Module for its vintage to verify angel communication.
Table 134: TEST #52 Control Channel Looparound Test
Error
Test
Code
Result
None
ABORT
2100
FAIL
PASS
Any
NO
BOARD
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
The test failed because the Media Module failed to return the Media
Module code or vintage.
Retry the command for a maximum of 5 times.
If the test still fails, use the busyout board, reset board, and release
busy board commands, and then retest.
If the problem continues, replace the Media Module.
Run the test again.
Communication with this Media Module is successful.
This is normal if the test is being done when (a) the board is not physically
in the system or (b) the system is booting up. Otherwise, there is some
inconsistency between the physical configuration and the data kept in the
system.
Verify that the board is physically in the system.
Verify that the system is not in a stage of booting up.
Retry the command at 1-minute intervals for a maximum of 5 times.
XXX-BD (Common Port Media Module)