Common Port Media Module Maintenance is a set of common tests used by all the Media Modules listed
in the tables below. The XXX-BD designation is also used on SAT displays when reset board is entered
with an empty Media Module slot, or with a Media Module type that is in conflict with the actual board
type administered for that slot. All Media Module suffixes (B,C, D, and so forth) are supported by "XXX-
BD."
When any of the Common Port Media Modules are physically removed from the backplane, no alarm
will be logged for approximately 11-minutes. (In the case of the MM712 Digital Line, MM720, and
INTUITY AUDIX, approximately 21-minutes will elapse before an alarm is logged.) When a Media
Module that has been removed is alarmed, the alarm type is minor and is classified as an on-board alarm.
The time delay permits maintenance activity to be performed without triggering an additional alarm.
Alarms are logged against only those common port Media Modules on which ports have been
administered. In a heavily loaded system, the interval between the removal of a Common Port Media
Module and the logging of the alarm may be several minutes longer. Suffixes are not shown; for a list of
all Media Modules supported, see the table in Chapter 2. Those that appear in bold type are documented
separately under their own maintenance object name.

XXX-BD Common Media Modules

The following list of Media Modules are listed by apparatus code.
Table 131: XXX-BD Common Media Module
Apparatus
Code
MM710
MM711
MM712

Error Log Entries and Test to Clear Values

Table 132: Common Port Media Module Maintenance Error Log Entries 1 of 2
Error
Aux
Type
Data
0*
0
1(a)
0
18(b)
0
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Name
DS1/E1 Interface - T1, 24 Channel - E1, 32 Channel
Analog Trunk and Line
Digital Line, 8-Port, 2-Wire DCP
Alarm
Associated Test
Level
Any
Any
Media Gateway
MINOR
removed or SAKI
Sanity Test (#53)
busy-out board
WARNING
GGGVS
XXX-BD (Common Port Media Module)
Type
Port
Port
Port
On/Off
Board
Test to Clear Value
Any
test board GGGVS sh
r 1
ON
OFF
release board GGGVS