Error Log Entries And Test To Clear Values - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
WAE-PORT (Wideband Access Endpoint Port)

Error Log Entries and Test to Clear Values

Table 127: Wideband Access Endpoint Maintenance Error Log Entries
Error
Aux
Type
Data
0*
0
18(a)
0
130(b)
1793(e)
3840(f)
Any
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
*
appropriate test description and follow the recommended procedures.
Notes:
The wideband access endpoint has been busied out by a busyout access-endpoint extension
command. No calls can be made to this extension.
The Media Module has been removed or has been insane for more than 11-minutes. To clear the
error, reinsert or replace the Media Module.
The Interface Media Module has failed. See MG-DS1.
The Port Audit and Update Test (#36) failed due to an internal system error. Enter status
access-endpoint extension and verify the status of the port. If the wideband access endpoint
port is out of service, enter release access-endpoint extension to put it back into service.
Retry the test command.
230
Alarm
Associated Test
Level
Any
Any
busyout access-
WARNING
endpoint
None
WARNING
None
Port Audit and Update
(Test #36)
Maintenance of the Avaya G350 Media Gateway
On/Off
Board
Test to Clear Value
Any
test access-endpoint
extension sh r 1
OFF
release access-endpoint
extension
ON
test access-endpoint
extension
test board GGGVSpp
long
June 2004

Advertisement

Table of Contents
loading