Translation Update Test (#146)

The Translation Update Test sends the circuit-pack-level information specified by System Administration
to the MG-DS1 Interface Media Module. Translation includes the following data administered for a
MG-DS1 Interface Media Module (see output of display ds1 GGGVS command): DS1 Link Length
between two DS1 endpoints, Synchronization Source Control, All Zero Suppression, Framing Mode,
Signaling Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
Table 117: TEST #146 Translation Update Test
Error
Test
Code
Result
ABORT
FAIL
PASS
Any
NO
BOARD

Echo Canceller Test (#1420)

CAUTION:
This test is executed only for MM710 Media Modules that have been administered on the
DS1 Media Module form to provide echo cancellation. The MM710 must be busied out
before this demand test is run.
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
Internal system software error.
Enter the display ds1 GGGVS command to verify the DS1-MM
Interface Media Module translation.
Translation data has been downloaded to the DS1-M Interface Media
Module successfully.
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the MG-DS1 interface if it is not already
administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then use the
busyout board command.
Use the reset board command.
Use the release busy board command.
Use the test board long command.
This should re-establish the linkage between the internal ID and the port.
MG-DS1 (DS1 Interface Media Module)