Error Log Entries And Test To Clear Values - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Table 101: ISDN Interface Reference Point definitions
LT
Logical Terminal
V
Primary Rate user/network (asymmetrical) trunk interface. The ECS is capable
of acting as the user or as the network side of this 1.544 - or 2.048-Mbps
interface.
R
Interface between Terminal Equipment and Network Termination
S
Basic Rate network-side 4-wire line interface
S/T
4-wire Basic Rate connection to a Network Termination
T
4-wire Basic Rate interface to a Network Termination.
TE
Terminal Equipment
U
Basic Rate network-side 2-wire line interface.
1
TN556B ISDN-BRI 4-Wire S/T-NT Line (A-law)
2
TN 2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
3
TN2198 ISDN-BRI 2-Wire U Interface
4
TN2198 ISDN-BRI 2-Wire U Interface
5
TN 2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
* Network Termination 2 (NT2), that terminates Layer 1 and higher layers. PBXs, LANs, and
terminal controllers typically provide NT2 functionality including protocol handling and
multiplexing for Layers 2 and 3.
† Network Termination 1 (NT1), that terminates Layer 1 and monitors maintenance, performance,
timing, power transfer, multiplexing, and multi-drop termination with contention resolution.

Error Log Entries and Test to Clear Values

Table 102: Error Log Entries and Test to Clear Values 1 of 2
Error
Aux
Type
Data
Associated Test
*
0
0
Any
1 (a
)
Any
None
257 (b
)
65535
Control Channel Loop Test
(#52)
513 (c
)
4352 to
4357
769 (d
)
4358
Maintenance of the Avaya G350 Media Gateway
June 2004
Avaya Communication Manager controlled maintenance
MG-BRI (BRI Trunk Media Module MM720 and MM722)
*
.
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test board GGGVM sh r 1
MINOR
ON
MINOR
ON
test board GGGVM r 20
None
ON
1 of 2