This test sends port level translation data from switch processor to the DS1 Interface Media Module to
assure that the trunk's translation is correct. Translation updates include the following data: trunk type
(in/out), dial type, timing parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk.
Table 44: TEST #36 Port Audit and Update Test
Error
Test
Code
Result
ABORT
1000
ABORT
1006
ABORT
90
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals for a maximum of 5 times.
System resources required to run this test were not available. The port may
be busy with a valid call.
Use display port GGGVSPP to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
If the port status is active but the port is not in use (no calls), check the
error log for error type 1025. The port may be locked up.
If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
The DS1 CO trunk is out of service.
Use status trunk to verify that the trunk is out of service.
If the trunk is out of service, determine why.
If it is OK to put the trunk back in service, use the release trunk
command to put the trunk back in service, and then retry the test.