Technician-Demand Tests: Descriptions And Error Codes - Avaya G350 Maintenance Manual

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Avaya Communication Manager controlled maintenance
XXX-BD (Common Port Media Module)
Technician-Demand Tests: Descriptions and
Error Codes
Always investigate tests in the order presented in the table below when inspecting errors in the system.
By clearing error codes associated with the NPE Audit, for example, you may also clear errors generated
from other tests in the testing sequence.
Table 133: Technician-Demand Tests
Order of Investigation
NPE Audit Test (#50)
Note: This Test will ABORT with
code 1412
Ringing Application Test (#51) (a)
Note: This Test will ABORT with
code 1412
Control Channel Looparound Test
(#52)
SAKI Sanity Test (#53) (b)
Neon Test (#220) (c)
Note: This Test will ABORT with
code 1412
*D = Destructive; ND = Nondestructive
Notes:
This is only applicable to Analog Line Media Modules.
The SAKI Sanity Test is run on other Media Modules only when they are reset via the reset
board command.
This is only applicable to MM711 Analog Line Media Modules.
236
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
Maintenance of the Avaya G350 Media Gateway
Reset
Board
Sequence
D/ND*
ND
D
ND
June 2004

Advertisement