Speed Setpoint Smoothed; Actual Speed Smoothed; Dc Link Voltage Smoothed; Absolute Actual Current Smoothed - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

1:
30:
Note
The drive can only be switched on when in the "Ready" state (p0009 = 0).
p0010
Drive commissioning parameter filter 2
Changeable: C2(1), T
Min: 0
Description:
Setting parameter filter 2 for commissioning the drive.
Value:
0:
1:
3:
95:
NOTICE
For p0010 = 95:
The safety commissioning Wizard must be carried out in the web server after changing safety parameters. These
changes become effective after carry out all of the commissioning steps of the wizards.
Note
The drive can only be switched on when in the "Ready" state (p0010 = 0).
r0020

Speed setpoint smoothed

Data type: FloatingPoint32
Description:
Displays the smoothed speed setpoint at the speed controller input.
r0021

Actual speed smoothed

Data type: FloatingPoint32
Description:
Displays the smoothed actual value of the motor speed.
Dependency:
See also: r0063
r0026

DC link voltage smoothed

Data type: FloatingPoint32
Description:
Displays the smoothed actual value of the DC link voltage.
Dependency:
See also: r0070
r0027

Absolute actual current smoothed

Data type: FloatingPoint32
Description:
Displays the smoothed absolute actual current value.
Dependency:
See also: r0068
r0031
Actual torque smoothed
Data type: FloatingPoint32
Description:
Displays the smoothed torque actual value.
Dependency:
See also: r0080
r0032
Active power actual value smoothed
Data type: FloatingPoint32
Description:
Display for the smoothed actual value of the active power.
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Device configuration
Parameter reset
Data type: Integer16
Max: 95
Ready
Only Siemens internal
Motor commissioning
Safety Integrated commissioning
P group: Displays, signals
P group: Displays, signals
P group: Displays, signals
P group: Displays, signals
P group: Displays, signals
P group: Displays, signals
Parameters
12.2 List of parameters
P group: All groups
Def: 1
Scaling: p2000
Scaling: p2000
Scaling: p2001
Scaling: p2002
Scaling: p2003
Scaling: r2004
229

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents