Faults and alarms
13.2 List of faults and alarms
Cause:
The pole position identification routine was unsuccessful.
Fault value (r0949, interpret decimal):
1: No current is established.
2: The starting current is not zero.
3: The selected max. distance was exceeded (p1981).
4x: The measuring signal does not permit a clear evaluation.
5: The max. current was exceeded during the measurement.
6: The current measurement must be re-calibrated.
7x: The Sensor Module does not support the pole position identification routine.
8: The pole position identification routine current required is greater than the max. current.
9: The set pole position identification routine current is zero.
10: Data set changeover during the pole position identification.
11: The encoder adjustment to determine the commutation angle is active (p1990 = 1) and the encoder without zero mark
is not finely synchronized or does not have any valid data.
100: motion-based pole position identification, 1st and 2nd Measurements differ. Motor blocked or current (p1993) too low.
101: Motion-based position position identification, insufficient motion, motor blocked or current (p1993) too low.
102: Motion-based pole position identification, brake is being used and is closed. The motion-based position position
identification in conjunction with the brake is not permitted.
103: Motion-based pole position identification without encoder.
104: Motion-based pole position identification, speed actual value not zero after stabilizing time.
200: Elasticity-based pole position identification, internal error in the arctan calculation ( 0/0 ).
201: Elasticity-based pole position identification, too few measuring points that can be evaluated.
202: Elasticity-based pole position identification, outliers in the measurement series.
203: Elasticity-based pole position identification, maximum rotation without current.
204: Elasticity-based pole position identification, no positive edge found.
205: Elasticity-based pole position identification, the result of the Fourier transformation differs by more than 480 °
electrical / p3093 from the rough estimate.
206: Elasticity-based pole position identification, plausibility test unsuccessful.
207: Elasticity-based pole position identification, no negative measured value found.
It is possible that all measured values are identical. The expected deflection was not able to be reached, either because
the expectation is too high or not enough current was able to be established.
208: Elasticity-based pole position identification, measuring current is 0.
209: Elasticity-based pole position identification, the selected max. distance was exceeded (p3095).
210: Elasticity-based pole position identification without encoder.
250 ... 260:
Elasticity-based pole position identification, more than 3 attempts have been made and fault value 200 ... 210 output.
Example:
Fault value= 253 --> more than 3 attempts have been made and fault value 203 output.