Completing The Safety Commissioning; Commissioning Step 5 - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

1. To change the time interval, click in the "Test stop timer" field. An input dialog with the same
name opens.
Set the timer interval here and confirm by clicking "OK".
The remaining time up to the test stop is determined automatically and displayed.
2. Click "Continue".
The "Completion" commissioning step is activated.
6.8.1.6

Commissioning step 5

Completion
You have made all of the settings for commissioning the drive-integrated safety functions. If,
up until now a safety password has not been configured, then it can now be configured in this
step (see the following chapter).
1. Click "Finish".
The following prompt appears. Click "Finish" again to confirm the prompt.
Figure 6-26
If both checkmarks are checked, the converter imports the settings of the safety
commissioning and performs a restart when the user clicks "Finish".
After the restart, the commissioning of the drive-integrated safety functions is completed
and the browser once again shows the home page of the web server.
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA

Completing the safety commissioning

Commissioning and diagnostics in the Web server
6.8 Safety settings
145