6.8.2

Safety diagnostics

The most important information on the safety settings and the states of the converter are
displayed using the safety diagnostics.
Select "Safety" and "Safety Diagnostics" in the navigation.
Figure 6-29

Display of the safety functions

You receive the following individual information via separate display areas:
● "Diagnostics of the safety functions"
Shows which safety functions have been activated in the converter.
● "Status"
Information on the status of the converter. If a forced checking procedure is required, then
this is displayed. The times for the forced checking procedure of the timer and the remaining
time up to the forced checking procedure are displayed.
The display area also shows whether internal events (e.g. software errors in the converter
or a discrepancy in the monitoring channels) have taken place and whether the
communication is OK.
● "Checksums"
Uses the safety logbook to determine changes to safety parameters and to indicate if a
component has been replaced/exchanged. Shows changes in the form of functional
checksums with time stamps.
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Commissioning and diagnostics in the Web server
6.8 Safety settings
149