Alarms - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

7.4

Alarms

Alarms
Alarms have the following properties:
● Alarms have no direct influence on the drive.
● Alarms disappear again when the cause is eliminated.
● Alarms cannot be acknowledged.
● Alarms are displayed as follows:
– In the PLC according to the PROFIdrive message class
– On the drive via LEDs
– At the drive using the three-digit display according to the PROFIdrive message classes
– In the Web server via the "Diagnostics - Messages" view
Alarm code or alarm value describe the cause of the alarm.
Reference
You can find additional information on alarms in Chapter "Overview of faults and alarms
(Page 291)".
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Diagnostics
7.4 Alarms
173