Installing
5.4 Connecting the converter and the motor
• 0.2 mm
• AWG: 26 ... 12
Connecting the external 24 V supply
Connect a 24 V power supply to the converter.
①
②
Figure 5-17
The terminals are spring-loaded terminals.
Permissible conductor cross-sections for single-core connection or for the connection of
flexible cables with end sleeves:
• 0.2 mm
• AWG: 26 ... 12
Connecting high-speed digital inputs, temperature monitoring for external braking resistor and fail-safe
digital input
Digital inputs DI 0 and DI 1 are high-speed digital inputs and can be used as measuring inputs.
Digital inputs DI 2 and DI 3 form a fail-safe digital input.
The temperature monitoring for an external braking resistor can be connected to DI 4. When
the temperature of the external braking resistor is too high, the converter shuts down the motor.
Figure 5-18
The terminals are spring-loaded terminals.
Permissible conductor cross-sections
• for single-wire connection: 0.2 mm
• for flexible cables with end sleeves: 0.25 mm
• for flexible cables with end sleeves with plastic protection: 0.25 mm
102
... 2.5 mm
2
2
24 V external
Loop-through for additional converters
X124 - 24 V external
... 2.5 mm
2
2,
X130 - connector for digital inputs
... 1.5 mm
, AWG: 24 ... 16
2
2
... 1.5 mm
2
2
Operating Instructions, 12/2017, A5E41702836B AA
... 0.75 mm
2
2
SINAMICS S210 servo drive system