Hf Damping Module (Cu): Sign-Of-Life Missing; Hf Damping Module (Cu): Telegram Error - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

F37851

HF Damping Module (CU): Sign-of-life missing

Message value:
Component number: %1, fault cause: %2
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
DRIVE-CLiQ communication error from the HF Damping Module to the Control Unit.
The DRIVE-CLiQ component did not set the sign-of-life to the Control Unit.
Fault cause:
10 (= 0A hex):
The sign-of-life bit in the receive telegram is not set.
Note regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
Remedy:
Upgrade the firmware of the component involved.
Note:
HF Damping Module
F37860

HF Damping Module (CU): Telegram error

Message value:
Component number: %1, fault cause: %2
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Faults and alarms
13.2 List of faults and alarms
721

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents