Hf Damping Module: 24 V Overvoltage Alarm; Hf Damping Module: Supply Undervoltage; Hf Damping Module: Internal Fan Defective; Hf Damping Module: 24 V Overvoltage Fault - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

A37044 (F)

HF Damping Module: 24 V overvoltage alarm

Message value:
-
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
Fault in the 24 V power supply for the HF Damping Module.
- the 32.0 V threshold was exceeded.
Remedy:
Check the 24 V DC voltage supply of the HF Damping Module.
Note:
HF Damping Module
Reaction upon F:
NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY (POWER ON)
F37045

HF Damping Module: Supply undervoltage

Message value:
%1
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
Power supply fault in the HF Damping Module.
- the voltage monitor signals an undervoltage fault on the module.
Fault value (r0949, interpret decimal):
24 V voltage [0.1 V].
Remedy:
- check the 24 V DC voltage supply of the HF Damping Module.
- carry out a POWER ON (switch-off/switch-on) for the component.
- replace the module if necessary.
Note:
HF Damping Module
A37049

HF Damping Module: Internal fan defective

Message value:
-
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The internal fan of the HF Damping Module has failed.
Remedy:
Check the internal fan of the HF Damping Module and replace if necessary.
F37050

HF Damping Module: 24 V overvoltage fault

Message value:
-
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
The voltage monitor signals an overvoltage fault on the module.
Remedy:
- check the 24 V power supply.
- replace the module if necessary.
F37052
HF Damping Module: EEPROM data error
Message value:
%1
Drive object:
All objects
Reaction:
NONE
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Faults and alarms
13.2 List of faults and alarms
713

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents