General Data, Converter - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

Technical specifications
8.2 Technical specifications of the converter
8.2.3

General data, converter

Property
Line voltage
Output voltage
Input frequency
Output frequency
Relative supply short-circuit
power
Power factor λ
Overvoltage category to IEC/
EN 61800-5-1
Pulse frequency
Short-circuit current rating
(SCCR) and branch protection
Degree of protection according
to EN 60529
Electronics power supply
Control mode
Protection functions
Technical data of the digital inputs
Type
Number
● Low level
● High level
● Current consumption
● Delay time, typ. L → H
● Delay time, typ. H → L
● Electrical isolation
Conductor cross section, max.
202
Version
200 V ... 240 V 1 AC, ±10 %
0 V 3 AC ... input voltage
50 Hz ... 60 Hz, ±10%
0 ... 550 Hz
RSC ≥ 25
> 0.9
● Up to 2000 m: The converter insulation is designed for surge voltages of overvoltage
category III.
● More than 2000 m: The surge voltages must be limited to values of overvoltage category
II, using an isolation transformer, for example.
8 kHz
≤ 65 kA rms
Branch protection and short-circuit strength according to UL and IEC
Protective devices
109748999)
IP20
Must be installed in a control cabinet
24 V DC, -15% ... +20%, I
Servo control
Ground fault protection, output short-circuit protection, overvoltage/undervoltage protection,
I2t detection, IGBT overtemperature protection
High-speed digital inputs
for probe or reference
marks
2 (DI 0, DI 1)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
6 mA
5 µs
50 μs
No
1.5 mm²
(https://support.industry.siemens.com/cs/ww/en/view/
= 1.6 A (PELV or SELV)
max
Fail-safe input
(F-DI)
1 (DI 2 and DI 3)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
5 mA
50 μs
100 µs
Yes
1.5 mm²
Operating Instructions, 12/2017, A5E41702836B AA
Digital input for monitoring
the temperature of an ex‐
ternal braking resistor
1 (DI 4)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
6 mA
5 µs
50 μs
No
1.5 mm²