SECTION 8

Troubleshooting

8-1 Troubleshooting
This section lists the errors that may occur during Z500 operation, along with their probable causes and
remedies.
The letters used in the reference page column represent the following reference materials:
Setup: Setup Manual
Operation: Operation Manual (this manual)
Error message
No edge detected.
Redo settings.
Environment is set to
select scenes via terminal
block.
The reference height and
position have been
updated.
Check the settings for
measurement items.
Too many items to
register.
Perform registration after
deleting unnecessary
items.
No measurement point
detected.
Redo settings.
Meas method will be
changed.
All scene data will be
cleared.
No more functions
settable.
Redo the settings.
Z500
Operation Manual
184
Causes and remedies
- Is the workpiece inside the measurement range?
- Is the measurement performed correctly?
Check this on the image monitor screen.
Reason
The edge to be determined as the reference position could not
be found during reference registration.
Using the System/Environment screen check if Scene has
been set correctly.
Reason
An error has occurred in Scene.
Check whether the setting contents of the measurement items
are correct.
Reason
The reference was registered after the measurement items
had been set. When using the position compensation function,
set Compensatn and Meas set in this order.
Delete all unnecessary measurement items, and then set the
necessary items again.
Reason
The number of measurement points exceeds the allowable
limit of the Z500.
- Is the workpiece inside the measurement range?
- Is the measurement performed correctly?
Check this on the image monitor screen.
Reason
The edge to be determined as the reference position could not
be found during reference registration.
Data integration cannot be ensured when the measurement
method is changed. All settings for scene data are returned to
their default settings.
Change the setting of unnecessary functions.
Example
- Set Conditions/Details/Profile to None.
- Set the position compensation to None.
- Delete all unnecessary measurement items.
- Delete Output/Analog/Profile.
Reference
Setup: page 28
Operation: page 30
Operation: page 146
Operation: page 70
Operation: page 87
Setup: page 28
Operation: page 30
——
Operation: page 96
Operation: page 64
Operation: page 70
Operation: page 100