SECTION 7
I/O Format
• SENSM
CHECK
Z500
168
Operation Manual
......
Function 1
Sets the sensitivity adjustment method to Multi and obtains the
optimum sensitivity for the workpiece.
SENSM
Input
delimiter
Command executed correctly
Output
Command not executed correctly
Example
SENSM
Input
:
delimiter
Output
: 17 25
delimiter
The optimum sensitivity is in the range of 17 to 25.
......
Function 2
Sets the sensitivity adjustment method to Multi and changes the
sensitivity level, turns the Laser OFF, and changes adjustments gradation.
SENSM <Sensitivity level A> <Sensitivity level B> <Adjustment
Input
gradation >
delimiter
Specify values between 0 and 31 for sensitivity level A and sensitivity level B.
• The sensitivity is set to the optimum level between A and B. Do not set A to a
value larger than B.
• If the same value is set for A and B, the sensitivity will be fixed at that level.
• If both A and B are set to 0, the laser will turn OFF.
(However, a measurement error will be exhibited.)
As a target value of the sensor sensitivity adjustment gradation, specify 120 to
220. If this setting is omitted, the gradation will be set to 170 (default setting).
Laser OFF Delay Time
The total time required for turning OFF the laser is less if terminal block input is used.
If the laser must be turned OFF instantaneously, use the LD-OFF input terminal.
REFERENCE
Refer to page 154 for information on how to input terminals.
Output
Command executed correctly
Command not executed correctly
: <Sensitivity level A>
<Sensitivity level B>
delimiter
: ER
delimiter
: OK
delimiter
: ER
delimiter