Contents of Display and Output
Note:
Profile (Profile)
If there is a process line where the workpieces cannot be measured due to
different reflectance or other causes, the data of such line can be obtained by
interpolating the data acquired from the lines that allow measurement as
desired.
Example: An output profile of a portion interfering with the measurement.
Peak/bottom Measurement Width (Peak/btm width)
The average over a specified region when measuring the peak or bottom is
output as the measurement value. The region can be specified in pixel units.
Setting a larger value will stabilize the measurement value.
Display/Output
Judgment results display
Terminals Judgment output (See note.)
RS-232C
4-20mA
Analog Output
±5V
The numbers of the output terminals vary depending on the output numbers.
Selection
A measurement error signal is output for a portion interfering with the
None
measurement.
For a portion interfering the measurement, measured values obtained
Intrpolate*
before and after the error are interpolated and the result is output.
A portion interfering
with measurement
Height
When selecting None :
A portion interfering
with measurement
Not interpolated
Peak point
Hold
ERROR is displayed.
ERROR is output.
The previous
Measurement error is output.
status is held.
22mA min.
+6V min.
Description
The asterisk (*) indicates the default setting.
Position
When selecting Intrpolate :
A portion interfering
with measurement
1pixel*, 5pixel, 9pixel, 13pixel, 17pixel,
Selection
21pixel, 25pixel, 29pixel,
The asterisk (*) indicates the default setting.
SECTION 4
Menus for Expert Menu
Clamp
Interpolation by using
measurement data of
the neighboring areas
Z500
Operation Manual
99