• TREND (or T)
Function
measurement under the Trigger setting.
Perform the setting as shown below, before using the command.
CHECK
Set the trigger input method to External or Self.
For details on the Trigger function, refer to page 90.
For details on how to set the Trend Monitor's display contents, refer to page 118.
• Specify an output number between 0 and 7.
• Specify an output coefficient between 1 and 1,000.
• The output coefficient is the number of intervals between measurements that
• The number of data items that will be output can be calculated using the
Measurement time
Number of measurements
output (The number is rounded up to the nearest integer.)
......
Obtains the measurement values from the start to the end of the
REFERENCE
REFERENCE
TREND (or T) <Output number> <Output coefficient>
Input
Output number
Meaning
0
OUT0
1
OUT1
2
OUT2
3
OUT3
4
OUT4
5
OUT5
6
OUT6
7
OUT7
are output.
formula below.
÷
Sampling time = Number of measurements
Scn 0
Run
Thru
Start to End (Measurement time)
(Selectable in Trigger setting.)
÷
Measurement coefficient = Number of data items
Sampling time
XX.XXms
Measurement results
Sampling time
SECTION 7
I/O Format
delimiter
Z500
173
Operation Manual