The procedure for make trigger settings under the following details is explained
below.
The difference between the maximum value and minimum value of the workpiece height is output.
Operational Flow
#1
#1
Display Waveforms in the Trend Monitor
Use the waveform to decide the trigger level and to set the measurement start
position.
Set the screen mode to Thru in advance.
CHECK
Refer to page 118.
1.
Press the SHIFT + Right Keys or SHIFT
+ Left Keys several times to switch to
Trend Monitor.
2.
Pass the workpiece under the Sensor
and display the waveform.
3.
The instant the waveform representing
the workpiece is displayed, press the
TRIG Key.
The waveform display is fixed.
Measurement item OUT0 : Height
Trigger input method Self
Hold setting (see note) Peak-Peak
Note: Set the Hold setting by using Meas set in advance.
Refer to page 84.
#2
Page 91
Set the Trigger Input
Display Waveforms
Method
in the Trend Monitor
(Trigger Mode)
(Through Mode)
REFERENCE
#3
Page 92
Page 95
Confirm Trigger
Settings
Scn 0
Thru
OUT 0
+0005.18800
S+
/
Scn 0
Set
Thru
SECTION 4
Menus for Expert Menu
Run
9.96ms
1div x: 1.000 [s]
y:+10.0000 [mm]
Zero's OFF
mm
PASS
:Display S+ENT:Adjust
The symbol changes.
1div x: 1.000 [s]
y:+10.0000 [mm]
Z500
Operation Manual
91