Omron Z500 Operation Manual page 99

Profile measuring system
Hide thumbs Also See for Z500:
Table of Contents

Advertisement

Judgment value hysteresis width (judgement width)
Set the hysteresis width for Judgment limits.
Example: HI: 100.000 mm; LO: 80.000 mm
Edge Detection Hysteresis Width (Edge width)
Set the hysteresis width of edge detection.
Change the edge width when edge detection is unstable.
Example: Edge level: 80.000 mm
Smoothing (Smoothing)
Use this function to smooth the measured images.
Noise removal (Noise)
Other than images with a setting pixel will be regarded as noise and excluded
from measurement.
Setting range
0.00000 to 9999.99999
The default setting varies depending on the Sensor connected.
Judgment value hysteresis width: 0.05 mm
HI
(100.0000)
LO
(80.0000)
OFF
HIGH
ON
OFF
Output
LOW
ON
OFF
PASS
ON
Setting range
0.00000 to 9999.99999 (0.00000*)
Edge level hysteresis width: 0.0500 mm
Edge level
(80.0000)
Selection
None
No smoothing.
Weak*
Smoothing is performed at a low level.
Strong
Smoothing is performed at a high level.
The asterisk (*) indicates the default setting.
Selection
0pixel, 1pixel, 2pixel, 3pixel, 4pixel*, 5pixel, 6pixel, 7pixel,
Hysteresis(0.0500)
Resets at 99.9500 mm
The asterisk (*) indicates the default setting.
Hysteresis (0.0500)
Edge position
Description
The asterisk (*) indicates the default setting.
SECTION 4
Menus for Expert Menu
Hysteresis(0.0500)
Resets at 80.0500 mm
Z500
Operation Manual
97

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Z500-mc15eZ500-mc10e

Table of Contents