Use this function to measure transparent workpieces. This function is also
useful to shorten the response time in Sensitivity/Multi. Normally, these
conditions can be left at the default settings. After changing the settings, perform
a workpiece measurement to check that measurement can still be performed
correctly.
The setting can be performed through the adjustment menu.
CHECK
Refer to page 28.
1.
Select Image/Details.
The setting screen for sensitivity details will be displayed.
2.
Make the settings for each item.
3.
Select End.
The setting will be registered and the screen in (1.) will return.
Seleciton/
Item
Setting range
Frnt*
Surface
Back
Upper
0 to 31(31*)
Lower
0 to 31(1*)
Gradations 120 to 220(170*)
REFERENCE
Description
The reflecting surface for which sensitivity adjustment
is performed is selected. To measure the back side of
a transparent workpiece, select Back. Normally (i.e.,
when measuring opaque workpieces), this setting can
be left as Frnt.
Specify the range to be adjusted the sensitivity.
This function is effective when sensitivity adjustment
method is set to Auto or Multi. If the adjustment range
is small, the response time for switching sensitivity will
be short.
Set the target gradation for sensor sensitivity
adjustment.
The asterisk (*) indicates the default setting.
Scn 0
Set
Image
Meas method
Compensatn
Region
Meas set
Sensitivity
Conditions
Details
Output
Scn 0
Set
Surface
Upper
Lower
Gradations
SECTION 4
Menus for Expert Menu
:
Frnt
:
[31]
:
[ 1]
:
[170]
End
Z500
Operation Manual
63