Omron Z500 Operation Manual page 63

Profile measuring system
Hide thumbs Also See for Z500:
Table of Contents

Advertisement

When selecting Fixed
1.
Select Image/Sensitivity.
The selections for sensitivity adjustment will be displayed.
2.
Select Fixed.
The screen for setting the sensitivity level will be displayed.
3.
Select the level using the Up and
Down Keys while monitoring the
image on the monitor.
The level displayed first is the level
selected by the Z500 for the work-
piece being measured. Adjust the
level while monitoring the line bright-
ness graph and the received level on
the monitor.
120 max. : Insufficient light density
255 min. : Excessive light density
4.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
SECTION 4
Menus for Expert Menu
Scn 0
Set
Image
Meas method
Compensatn
Region
Meas set
Sensitivity
Conditions
Details
Output
Auto
Fixed
Multi
Line Brightness
NEAR
LV 15
BRIGHT
Sen0
Sen1
DARK
Received level
FAR
[ 15]
LV
[ 170]
PEAK
[ .]
LV
[ ]
PEAK
Z500
61
Operation Manual