SECTION 7
I/O Format
Output Terminals
Terminal
Functions as a BUSY signal. Indicates that the Z500 is performing Trigger measurement. If trigger
DO19
function is set, this terminal can be used to confirm trigger operation.
DO0
Functions as a HIGH terminal for OUT0.
DO1
Functions as a PASS terminal for OUT0.
DO2
Functions as a LOW terminal for OUT0.
DO4
Functions as a HIGH terminal for OUT1.
DO5
Functions as a PASS terminal for OUT1.
DO6
Functions as a LOW terminal for OUT1.
Used to control the timing with which measurement results are obtained by the external device.
GATE
Turns ON for a time set so that the external device can obtain the judgment results of the output
numbers for which Hold is set.
DO8
Functions as a HIGH terminal for OUT2.
DO9
Functions as a PASS terminal for OUT2.
DO10
Functions as a LOW terminal for OUT2.
DO12
Functions as a HIGH terminal for OUT3.
DO13
Functions as a PASS terminal for OUT3.
DO14
Functions as a LOW terminal for OUT3.
DO3, DO7
Function as error terminals for OUT0, OUT1, OUT2, and OUT3 respectively.
DO11, DO15
Input terminals
Terminal
TRIGGER
Inputs the measurement trigger from a sync sensor such as a photoelectric sensor.
NOTICE
Z500
158
Operation Manual
(3) Operation using the Hold function
Example: If Hold is set for some but not all outputs (Judgment output A)
Settings:
OUT0 and OUT1: Hold set
OUT2 and OUT3: Hold not set
OFF
TRIGGER
ON
OFF
DO19
ON
(
)
BUSY
DO0 to DO2
DO4 to DO6
OFF
(**)
GATE
ON
DO8 to DO10
(OUT2 judgment results)
DO12 to DO14
(OUT3 judgment results)
(*)
Sampling time max.
(**)
The GATE signal is output only for the terminals of output numbers for which Hold is set.
Ensure that the TRIGGER turns ON while the GATE signal is OFF. If the TRIGGER turns
ON while the GATE signal is ON (including at GATE ON delay), outputs may not operate
properly.
During Trigger
measurement
MAX(*)
OUT0 Judgment results
OUT1 Judgment results
GATE
GATE
ON Delay
ON time
Sampling time
Function
Function