Automatic corrections
7.13
Use of scale
correction
Atmospheric correc-
tion DD1
Air humidity
Air humidity
correction
Index n
86
The following automatic corrections are made:
Line of sight error
Tilting axis error
Earth curvature
Circle eccentricity
Compensator index error
Vertical index error
Standing axis tilt
Refraction
ATRplus zero point error

Scale Correction

By entering a scale correction, reductions proportional to distance can be
taken into account.
Atmospheric correction.
Reduction to mean sea level.
Projection distortion.
The slope distance displayed is correct if the scale correction in ppm, mm/km,
which has been entered corresponds to the atmospheric conditions prevailing
at the time of the measurement.
The atmospheric correction includes:
Adjustments for air pressure
Air temperature
Relative humidity
For highest precision distance measurements, the atmospheric correction
should be determined with an accuracy of 1 ppm. The following parameters
must be redetermined:
Air temperature to 1 °C
Air pressure to 3 mbar
Relative humidity to 20%
The air humidity influences the distance measurement if the climate is
extremely hot and damp.
For high precision measurements, the relative humidity must be measured and
entered along with the air pressure and the temperature.
ppm
+5
+4
+3
+2
+1
+0
-20
-10
0
10 20 30 40 50
TS_104
Type
Combined EDM
100%
80%
60%
40%
ppm
Air humidity correction
20%
[mm/km]
%
Relative humidity [%]
°C
°C
Air temperature [°C]
Index n
1.0002863
Carrier wave [nm]
658
Technical Data