15.2.2 Settings for Pulsar Operation

For using the pulsar operation, set the parameters in the two dialog boxes "Pulse input" and
"Parameter settings" of Configurator PM7.
 Pulse input setting
Select "Pulsar" from the items of pulse input application.
Item
Pulse input application
Pulse input rotation
direction
Pulse input method
Pulse input multiplication
 Parameter settings menu
• For the item of the "pulsar operation code" of the axis on which the pulsar operation is
performed, select the channel number of the connected pulse input.
• The movement amount per an 1-pulse signal from the pulsar can be changed by setting the
ratio numerator and ratio denominator for the input signal of the pulsar.
Item
Operation setting code
Pulsar operation ratio
numerator
Pulsar operation ratio
denominator
Pulsar input method
Pulsar operation maximum
speed
Setting example
0: Pulsar
0: Forward
0: 2-phase input
2: Multiply by 4
Setting example
0: Pulse input CH1
2
1
2: Speed restriction (time
hold)
500
15.2 Setting and Operation of Pulsar
Settable range
0: Pulsar
0: Forward, 1: Reverse
When using the pulsar, only "0: 2-phase input" can be set.
When using the pulsar, only "2: Multiply by 4" can be set.
Settable range
0: Pulsar input CH1, 1: Pulsar input CH2, 2: Pulsar input
CH3, 3: Pulsar input CH4
1-32,767
1-32,767
0:Standard operation , 1: Speed restriction (pulse hold), 2:
Speed restriction (time hold)
pulse: 0 -2,147,482,624 pps
15-9

Advertisement

Table of Contents
loading