Panasonic FP-XH M8N16PD User Manual page 73

Programmable controller
Table of Contents

Advertisement

Contact
Target
allocation
axis
Y1240
Axis 1
Y1241
Axis 2
Y1242
Axis 3
Y1243
Axis 4
Y1244
Axis 5
Y1245
Axis 6
Axis 7
Y1246
(virtual)
Axis 8
Y1247
(virtual)
Y1248
-
-Y124F
Y1250
Axis 1
Y1251
Y1252
Axis 2
Y1253
Y1254
Axis 3
Y1255
Y1256
Axis 4
Y1257
Y1258
Axis 5
Y1259
Y125A
Axis 6
Y125B
Y125C
Axis 7
Y125D
Y125E
Axis 8
Y125F
Y1260
-
-Y126F
(Note 1): When using the virtual axes, the I/O numbers allocated vary according to the number of virtual axes.
When selecting virtual 1st
axis
When selecting virtual 1st
and 2nd axes
3.4 Detailed I/O Information of Motion Control Part
Name
Description
Requests the warning clear of the corresponding axis.
Warning clear
request
The warning logs are cleared by turning on this signal.
-
-
RTEX general-
purpose output 1
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
Contact for the RTEX general-purpose output connected to the
purpose output 2
corresponding AMP.
The input status of this contact does not affect on the operation
RTEX general-
purpose output 1
of the motor and unit.
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
purpose output 2
RTEX general-
purpose output 1
RTEX general-
purpose output 2
-
-
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
1st axis".
The I/O number of "Axis 7 (virtual)" in the above table is allocated to "virtual
1st axis".
The I/O number of "Axis 8 (virtual)" in the above table is allocated to "virtual
2nd axis".