Specifications
Item
Interrupt program
Sampling trace
PLC link function
Constant scan
Security Function
Self-diagnosis function
Rewriting during RUN
Controller input
High-speed
When pulse I/O
counter
cassette is
installed
Controller
output
Pulse output
/ PWM
When pulse I/O
output
cassette is
installed
Pulse catch input
interrupt input
Periodical interrupt
Potentiometer input
Input time constant processing
Calendar timer
(real-time clock)
(note 5)
Flash-ROM backup
Battery backup
Battery lifetime
(Note5): Precision of calendar timer (realtime clock) (At 0 degree: less than 119 seconds per month, At 25 degrees:
less than 51 seconds per month, At 55 degrees: less than 148 seconds per month)
(Note 6): It will be cleared upon connection of the power if no battery installed or the battery is empty.
(Note 7): The battery life is the value with the power supply not connected. The actual service life may be reduced
due to use conditions.
26-4
Specifications
Interruption via external input or interruption when the target value of the high-
speed counter is consistent × 8 programs
Periodical interrupt (0.1 ms unit, 0.5 ms unit or 10 ms unit) × 1 program
Smapling by commands/Sampling at regular time intervals For one sampling: 16
bits + +3 words, 1000 samples)
Up to 16 units, (link relay 1024 points, link register 128 words) × 2.
(Baud rate: 115200 bps / 230400 bps)
Available (0 msec-350 msec)
Passwords (4-digit, 8-digit, 32-digit), upload protection
Watchdog timer, program syntax check
Available (Download during RUN, Program rewrite during RUN (Max. 512 steps)
Single-phase 8ch or 2-phase 4-ch Max. 10 kHz
Can not be installed
None
Can not be installed
8 points (Input of main unit: 8 points)
0.1ms-0.3s (0.1ms unit), 0.5ms-1.5s (0.5ms unit),
10ms-30s (10ms unit)
1ch (K0 - K4000)
Available (set via system register or instructions)
Year (last 2 numbers in the Gregorian calendar), month, day, hour (24h), minute,
second, week. As of 2099.
Applicable during leap years.
Available only when the master memory cassette AFPX-MRTC and battery are
installed
Guaranteed writing times: up to 10 thousand times
Automatic backup in case of power outage
Counter 16 points, internal relay 128 points, data register 315 words
Can be operated through the tool software or F-ROM read and write instruction
(F12 / P13)
Backup in data register 2K words
When optional batteries are used, all memory areas for operation can be backed
up
The hold / non-hold area can be set with the system register.
More than 5 years depending on the actual use condition (run 8 hours per day)
(note 7)