Panasonic FP-XH M8N16PD User Manual page 145

Programmable controller
Table of Contents

Advertisement

5. For performing the interpolation control, drag the icon of each axis to be
allocated for interpolation to the interpolation group field.
The figure below shows the cases when axis 1 and axis 2 are assigned to the
interpolation operation group.
6. Click the [OK] button.
The confirmation message is displayed.
7. Confirm the change and click [Yes].
Create the data table tab respectively according to the set group.
KEY POINTS
After setting the interpolation group, settings for the movements of the X-
axis, Y-axis or Z-axis and the interpolation operations will be added to the
data table and displayed on the tab as group [A] and [B].
Virtual axes and slave axes under synchronized control cannot be set to the
interpolation operation groups.
The master axis of the synchronous control can be set as the interpolation
group.
When changing the setting of "use of virtual axes", restart the power supply
after writing to the PLC. The set information will be reflected.
Press × to close during the edition to cancel and exit.
9.1 Axis Allocation for Use
9-3

Advertisement

Table of Contents
loading

Table of Contents