Panasonic FP-XH M8N16PD User Manual page 498

Programmable controller
Table of Contents

Advertisement

Specifications
Offset
Name
Address
Reserved for
H2E-H32
system
Emergency stop
H33
deceleration time
Reserved for
H34
system
Limit stop
H35
deceleration time
Reserved for
H36
system
Error stop
H37
deceleration time
Pulsar operation
H38
setting code
Pulsar operation
H39
ratio numerator
Pulsar operation
H3A
ratio denominator
26-42
Default Setting range and description
When the emergency stop is requested by I/O, it will be valid, and the
deceleration operation will complete in this deceleration time.
K100
Setting range: 0-10,000 (ms)
Any other settings will be errors.
When the limit is input, the deceleration operation will complete in this
deceleration time.
K100
Setting range: 0-10,000 (ms)
Any other settings will be errors.
When an error occurs, it will be valid, and the deceleration operation
will complete in this deceleration time.
K100
Setting range: 0-10,000 (ms)
Any other settings will be errors.
Select the channels of the pulse input circuit that will be the input for
the pulsar operation.
0: Pulse input CH1
K0
1: Pulse input CH2
2: Pulse input CH3
3: Pulse input CH4
Any other settings will be errors.
Sets the multiplier for the input pulse string in the pulsar operation.
(Number of command pulses) = (Pulse strings of input from pulsar) x
(Numerator of ratio of pulsar operation) / (Denominator of ratio of
K1
pulsar operation).
Retting range: K1-K32767
Any other settings will be errors.
Sets the divisor for the input pulse string in the pulsar operation.
(Number of command pulses) = (Pulse strings of input from pulsar) x
(Numerator of ratio of pulsar operation) / (Denominator of ratio of
K1
pulsar operation).
Setting range: K1-K32767
Any other settings will be errors.

Advertisement

Table of Contents
loading