 Pulse count control area
Offset
Name
address
Pulse count
H3A8
enable flag
Pulse count
H3A9
value change
request flag
H3AA
Reserved for system
~H3AF
Pulse input
H3B0
change value
H3B1
of CH1
Pulse input
H3B2
change value
H3B3
of CH2
Pulse input
H3B4
change value
H3B5
of CH3
Pulse input
H3B6
change value
H3B7
of CH4
 Pulse input monitor area
Offset
Name
address
H3C0
Pulse input value of CH1
H3C1
H3C2
Pulse input value of CH2
H3C3
H3C4
Pulse input value of CH3
H3C5
H3C6
Pulse input value of CH4
H3C7
Default Description
When the corresponding bit to each axis turns to 0, the count of pulse input
will start.
This flag is available only when setting the pulse input purpose to "High-
speed counter".
bit
Name
H0
Enable pulse count of CH1
0
Enable pulse count of CH2
1
Enable pulse count of CH3
2
Enable pulse output of CH4
3
15-4
When the corresponding bit to each axis changes to 1 from 0, the pulse
input will be changed to the pulse count change value that the pulse input
count value has been set.
This flag is an edge trigger. Always change this flag to 1 from 0 before
change.
bit
Name
H0
Change pulse count of CH1
0
Change pulse count of CH2
1
Change pulse count of CH3
2
Change pulse count of CH4
3
15-4
K0
K0
Set the pulse input values to be changed for each axis.
Range: ‐2,147,483,628 to 2,147,483,627
K0
K0
Description
Stores the pulse input values (pulsar, counter) according to the pulse input
purposes. The pulse input value is stored by integrating the pulse input
values until changing the pulse input purpose or clearing the pulse input.
Unit: Pulse
26.4 Positioning Memory
Default
Description
0
0: Count pulse input
0
1: Not count pulse input
0
0
Default
Description
0
0: Not change pulse
count values.
0
0→1: Change pulse count
0
values.
0
26-33