Panasonic FP-XH M8N16PD User Manual page 304

Programmable controller
Table of Contents

Advertisement

Auxiliary Function
 Example of operation (3) When a continuous table operation is performed
(Incremental)
Parameter
Control method
First table positioning movement
amount (Before change)
First table positioning movement
amount (After change)
f
5,000pls
1
2
A
Movement amount change request contact ON
Because of the increment setting, the stop position of the
B
table 2 also changes.
 Example of operation (4) When a continuous table operation is performed
(Absolute)
Parameter
Control method
First table positioning movement
amount (Before change)
First table positioning movement
amount (After change)
f
5,000pls
1
2
A
Movement amount change request contact ON
Because of the absolute setting, the stop position of the table
B
2 does not change.
17-20
Setting value
Incremental
5,000 (pls)
8,000 (pls)
f
8,000pls
1
t
A
Setting value
Absolute
5,000 (pls)
8,000 (pls)
f
8,000pls
1
t
A
B
2
t
B
2
t