Automatic Operation (Synchronous Control)
 Precautions when using phase shift amount
Specify the values when the phase shift amount is 0(%) for the parameter values of cam
1
pattern (starting phase, displacement and cam curve).
The starting phase of the section number 1 is 0(%). When any values other than 0(%), an
2
error will occur. For starting phases after the section number 2, specify arbitrary starting
phases. When reading and writing settings, the closest phase will be automatically calculated
within the unit from the resolution.
After setting the cam pattern when the phase shift amount is 0(%), set a phase shift
3
amount. When reading and writing settings, the closest phase amount will be automatically
calculated within the unit from the resolution.
For rewriting the cam pattern set on the tool software Configurator PM7 to a user program,
perform the following procedure.
Record the phase shift amount specified on Configurator PM7.
5
The phase shift amount has been added to the starting phase displayed on Configurator
6
PM7. Set the phase shift amount to 0(%) to confirm the parameter values of cam pattern
(starting phase, displacement, cam curve).
Use the parameter values acquired in ○ 6 on user programs. As for the starting phase, use
7
values to two decimal places.
Set the phase shift amount recorded in ○ 5 . As well as the starting phase, use values to two
8
decimal places.
12-38