 Synchronouse parameters: Electronic cam-related errors (5300H - )
Code
Name
Electronic cam - Cam
control synchronous
5300H
master axis cycle
setting error
Electronic cam - Used
5301H
cam pattern no. setting
error
Electronic cam - Cam
5302H
stroke amount setting
error
 Cam patterns-related errors
Code
Name
Cam pattern resolution
5400H
setting error
Cam pattern set
5401H
number setting error
Cam pattern section
5402H
function setting error
Cam pattern control
5403H
start position setting
error
Cam pattern start
5404H
phase setting error
Cam pattern
5405H
displacement setting
error
Cam pattern cam
5406H
curve no. setting error
Adjustment data total
5410H
no. setting error
Adjustment data no.
5411H
setting error
Adjustment data
5413H
control point setting
error
Out-of-range
5414H
adjustment data setting
error
19-24
Description
The setting for the cam
control synchronous master
axis cycle is incorrect.
The used cam pattern
number is out of the range.
The used cam pattern
number is not registered.
The setting for the cam stroke
amount is incorrect.
Description
The setting for the cam
pattern resolution is out of the
range.
The cam pattern set number
is out of the range.
The setting for the cam
pattern section function is out
of the range.
The setting for the cam
pattern control start position
is out of the range.
The start phase setting for
each section of cam pattern
is out of the range.
The displacement for each
section of cam pattern is out
of the range.
The curve number for each
section of cam pattern is out
of the range.
The total number of cam
pattern adjustment data is out
of the range.
The number of cam pattern
adjustment data is out of the
range. (cam pattern unit)
The control point of cam
pattern adjustment data is out
of the range.
The adjustment value of cam
pattern adjustment data is out
of the range.
Object
Recovery
Each
axis
Each
axis
Each
axis
Object
Recovery
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Each
axis
Measures
Check the set value.
If the error occurs
repeatedly with the correct
set values, consult your
Panasonic representative.
Measures
Check the set value.
If the error occurs
repeatedly with the correct
set values, consult your
Panasonic representative.