Instrument Panel Cluster Self Test - Volvo FM Handbook

Hide thumbs Also See for FM:
Table of Contents

Advertisement

Information display
70
5
If there are several fault codes or fault messages
for the same control unit, you can scroll through
the fault codes with ▲ and ▼. "Reset all" is
shown last in the list. This resetting only clears
the fault codes for the selected control unit.
6
If there are more than 20 fault codes/fault
messages for the selected control unit, the 21st
message will be "Too many fault messages". To
see those messages that are not shown, one or
more of the first messages must be reset.
7
Press "SELECT" to show more information on
the fault code. Fault codes are shown numerically
here. If the fault is inactive, both the time and
date for the fault are shown.
MID: Identification of control unit
PID: Identification of parameters
PPID: Volvo unique Identification of parameters
SID: Identification of components
PSID: Volvo unique Identification of
components
FMI: Identification of fault IDs
To reset the fault code, hold "SELECT" in for 1
second.

Instrument panel cluster self test

Indicator lamps test
1
Select "Tell-tales test, LEDs" with ▲ and ▼.
2
Confirm with "SELECT".
3
The tell-tales light up for approx. 5 seconds.
4
Cancel the test with "Esc"
Gauge test
1
Select "Gauge test" with ▲ and ▼.
2
Confirm with "SELECT".
3
The gauges make a diagnostic sweep.
The pointers move back and forth a few times,
between the end positions. They should not show

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fh

Table of Contents