Information display
98
2
If the selected control unit has no faults "No
faults" is displayed.
Press "Esc" to return to the previous menu.
3
If the selected control unit does not reply within 5
seconds the following is shown "Operation
failed" in the display.
Press "Esc" and try once more, see point 1.
Contact a workshop if necessary.
4
If the selected control unit has a fault code or
fault codes, it displays
1 Which control unit it applies to
2 Which parameter or component is faulty
3 Which type of fault it is
4 If the fault is active or inactive
5 How many times the fault has been registered
since the last reset
5
If there are several fault codes or fault messages
for the same control unit, you can scroll through
the fault codes with ▲ and ▼. "Reset all" is
shown last in the list. This resetting only clears
the fault codes for the selected control unit.
6
If there are more than 20 fault codes/fault
messages for the selected control unit, the 21st
message will be "Too many fault messages". To
see those messages that are not shown, one or
more of the first messages must be reset.
7
Press "SELECT" to show more information on
the fault code. Fault codes are shown numerically
here. If the fault is inactive, both the time and
date for the fault are shown.
MID: Identification of control unit
PID: Identification of parameters
PPID: Volvo unique Identification of parameters
SID: Identification of components
PSID: Volvo unique Identification of
components
FMI: Identification of fault IDs
To reset the fault code, hold "SELECT" in for 1
second.